Kinetics Noise Control
Home > Noise Control Building Materials > STC/IIC Sound Test Reports > Wood-Framed Construction > Above Frame
KINETICS®

STC/IIC Sound Test Data, Wood Above Framed Construction

Description STC IIC Sections Test #
1" Oak Hardwood Floor
3" Subfloor
  FIIC 15 AT001033
Requires Adobe Reader
3/4" Oak Hardwood Floor
3/4" Sleepers
1-1/2" Gypsum Concrete
2 Layers 1/2" Oriented Strand Board (OSB)
1" KINETICS RIM L-1-16
1" Oak Hardwood Floor
3" Subfloor
FSTC 50 FIIC 45 AT001034
Requires Adobe Reader
3/4" T&G Hardwood Floor
5/8" Plywood
1" KINETICS RIM Isolation Material
3-1/2" Timber Deck
ATSC 49 FIIC 48 AT001108
Requires Adobe Reader
3" Lightweight Concrete (polished)
1/2" Plywood
2" KINETICS RIM L-2-16
3-1/2" Wood Deck Subfloor
Steel Beam and Glue Lam Joist Support
No Ceiling
NNIC 62 FIIC 54 AT001071
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
51 39 AT001081
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
1" KINETICS Ultra Quiet SR Floorboard
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
53 51 AT001078
Requires Adobe Reader
Vinyl Flooring
1-1/2" Gypsum Concrete
5/8" KINETICS SR Floorboard
3/4" OxBoard
2x12 Joists
R-11 Fiberglass Insulation
1/2" Resilient Channel
5/8" Gypsum Board
FSTC 54 FIIC 53 AT001041
Requires Adobe Reader