Model UltraQuiet SR STC/IIC Sound Test Data

Description Acoustical Properties Sections Test #
STC IIC
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
1" Kinetics® Ultra Quiet SR Floorboard
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
Resilient Channel
2 Layers of 5/8" Gypsum Board
54 59 02143
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
1" Kinetics® Ultra Quiet SR Floorboard
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
53 51 02144
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
51 39 02146