Sound Transmission Class (STC) and Impact Insulation Class (IIC)

Description STC IIC Sections Test #
2" Topping Slab
Precast Concrete 14" Tee
54 24 A2-a
Requires Adobe Reader
4" Concrete Slab
1/2" Plywood
2" Kinetics® RIM L-2-12
2" Topping Slab
Precast Concrete 14" Tee
73   A2-b
Requires Adobe Reader
4" Concrete Slab
1/2" Plywood
2" Kinetics® RIM L-2-12
2" Topping Slab
Precast Concrete 14" Tee
  70 A3
Requires Adobe Reader
4" Concrete Slab
5/8" Plywood
2" Kinetics® RIM Q-2-12
4-7/8" Concrete Slab with 17" Tee
Drop in Acoustical Ceiling
FSTC 72 FIIC 68 A11
Requires Adobe Reader
3" Lightweight Concrete (polished)
1/2" Plywood
2" Kinetics® RIM L-2-16
3-1/2" Wood Deck Subfloor
Steel Beam and Glue Lam Joist Support
No Ceiling
NNIC 62 FIIC 54 08089
Requires Adobe Reader
4" Concrete Slab
1/2" Plywood
Kinetics® KIP-22-Q2 Isolation Pads
6" Concrete Slab
68 60 A13-a
Requires Adobe Reader
4" Concrete Slab
1/2" Plywood
2" Kinetics® RIM-Q-2-16
6" Concrete Slab
72 62 A13-b
Requires Adobe Reader
4" Concrete Slab
1/2" Plywood
2" Kinetics® RIM-Q-2-16
6" Concrete Slab
Kinetics® ICC Isolation Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
94 82 A13-c
Requires Adobe Reader
6" Concrete Slab
Kinetics® ICC Isolation Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
84 70 A13-d
Requires Adobe Reader
1" Oak Hardwood Floor
3" Subfloor
  FIIC 15 A14-a
Requires Adobe Reader
3/4" Oak Hardwood Floor
3/4" Sleepers
1-1/2" Gypsum Concrete
2 Layers 1/2" Oriented Strand Board (OSB)
1" Kinetics® RIM L-1-16
1" Oak Hardwood Floor
3" Subfloor
FSTC 50 FIIC 45 A14-b
Requires Adobe Reader
3/8" Plywood
2 Layers 3/4" Plywood
2" Kinetics® RIM-I-2-16
6" Concrete Slab
66 63 A15-a
Requires Adobe Reader
3/8" Plywood
3/4" Plywood
2 Layers 5/8" Gypsum Board
3/4" Plywood
2" Kinetics® RIM-I-2-16
6" Concrete Slab
71 64 A15-b
Requires Adobe Reader
8" Flexicore Precast Subfloor   B13
Requires Adobe Reader
Ceramic Tile
7/16" Glass Mesh Mortar Unit/Bond Coat
5/8" Kinetics® SR Floorboard
8" Flexicore Precast Subfloor
59 +38 IIC
B1
Requires Adobe Reader
Ceramic Tile
7/16" Glass Mesh Mortar Unit/Bond Coat
5/8" Kinetics® SR Floorboard
8" Flexicore Precast Subfloor
3-1/2" Fiberglass Fill in 10" Air Space
5/8" Gypsum Board on Resilient Channel
60 65 B3
Requires Adobe Reader
Vinyl Flooring
1-1/2" Gypsum Concrete
5/8" Kinetics® SR Floorboard
3/4" OxBoard
2x12 Joists
R-11 Fiberglass Insulation
1/2" Resilient Channel
5/8" Gypsum Board
FSTC 54 FIIC 53 B5
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
1" Kinetics® Ultra Quiet SR Floorboard
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
Resilient Channel
2 Layers of 5/8" Gypsum Board
54 59 02143
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
1" Kinetics® Ultra Quiet SR Floorboard
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
53 51 02144
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
51 39 02146
Requires Adobe Reader
Wood Flooring
2 Layers 3/8" Plywood
5/16" Kinetics® Soundmatt
1" Gypsum Concrete
5/8" Plywood
2x12 Joists
4" Mineral Fiber Batts
1/2" Resilient Channel
5/8" Fire-Rated Gypsum Board
58 54 B7-a
Requires Adobe Reader
Ceramic Tile
1/2" Wonderboard
5/16" Kinetics® Soundmatt
with Roofing Felt Underlayment
5/8" Plywood
2x12 Joists
4" Mineral Fiber Batts
1/2" Resilient Channel
5/8" Fire-Rated Gypsum Board
63 54 B7-c
Requires Adobe Reader
Ceramic Tile
1/2" Wonderboard
5/16" Kinetics® Soundmatt
6" Concrete Slab
60 53 B7-d
Requires Adobe Reader
Vinyl Floor Covering
1" Gypsum Concrete
3/4" Oriented Stand Board (OSB)
18" I-Joist
3" Mineral Fiber Batts
Resilient Channel
5/8" Gypsum Board
  FIIC 33 B8-a
Requires Adobe Reader
Vinyl Floor Covering
1" Gypsum Concrete
5/16" Kinetics® Soundmatt
3/4" Oriented Stand Board (OSB)
18" I-Joist
3" Mineral Fiber Batts
Resilient Channel
5/8" Gypsum Board
  FIIC 51 B8-b
Requires Adobe Reader
5/8" Hardwood Flooring
3/4" Plywood Subfloor
5/8" Kinetics® SR Floorboard
7" Concrete Slab
  FIIC 54 B9
Requires Adobe Reader
6" Concrete Slab 53 27 B10
Requires Adobe Reader
Floating Engineered Hardwood Floor
3mm Kinetics® IsoLayment BR
6" Concrete Slab
50 50
IIC 21
08097
Requires Adobe Reader
Floating Engineered Hardwood Floor
9mm Kinetics® IsoLayment BR
6" Concrete Slab
50 52
IIC 24
09010
Requires Adobe Reader
1/2" Thick Ceramic Tile
5mm Kinetics® IsoLayment HB
6" Concrete Slab
53 48
IIC 19
09020
Requires Adobe Reader
Engineered Hardwood Floor
Kinetics® IsoLayment BR 3mm
3/4" Plywood Sheating
R-19 Batt Insulation
12" I-Joist at 24" O.C.
Kinetics® WAVE Hanger
7/8" Drywall Furring (Hat) Channel
2 Layers 5/8" Type X Gypsum Board
60 57 IIC
Requires Adobe Reader

STC
Requires Adobe Reader
Ceramic Tile
Kinetics® IsoLayment HB 3mm
5/8" Plywood Sheating
3/4" Plywood Sheating
R-19 Batt Insulation
12" I-Joist at 24" O.C.
Kinetics® WAVE Hanger
7/8" Drywall Furring (Hat) Channel
2 Layers 5/8" Type X Gypsum Board
61 56 IIC
Requires Adobe Reader

STC
Requires Adobe Reader
6" Concrete Slab
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
2-1/2" Fiberglass Insulation compressed to 2"
5/8" Gypsum Board
66 44 C1
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
51 39 02146
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
54 57 02147
Requires Adobe Reader
6" Concrete Slab
Kinetics® IsoGrid Ceiling Hanger
6" Airspace Filled with Fiberglass Insulation
Cold Rolled Channel (CRC)
Drywall Furring Channel
2 Layers 5/8" Gypsum Board
63 50 02152
Requires Adobe Reader
3/8" Wood Floor
1-1/2" Concrete Slab
5/8" Plywood
2x10 Joists
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
51 40 C2-a
Requires Adobe Reader
3/8" Wood Floor
1-1/2" Concrete Slab
3/4" Plywood
2x10 Joists
Kinetics® ICW Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
76 62 C2-b
Requires Adobe Reader
Carpet
3/8" Carpet Pad
1-1/2" Concrete Slab
5/8" Plywood
2x10 Joists
Kinetics® ICW Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
73 89 C2-c
Requires Adobe Reader
3/8" Wood Floor
3/4" Plywood
2x10 Joists
Kinetics® ICW Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
59 52 C2-h
Requires Adobe Reader
Hardwood Floor Over Vapor Barrier Mat
1-1/4" AccuCrete Gypsum-Based Concrete Slab
3/8" AccuQuiet Resilient Floor Underlayment
3/4" Plywood
2 Layers Existing 1" x 6" Wood Subfloor
2x10 Joists 16" OC
Kinetics® ICW Ceiling Hanger
6" Fiberglass Insulation
Cold Rolled Channel (CRC)
Drywall Furring Channel
2 Layers 5/8" Gypsum Board
FSTC 57 FIIC 62 AT001087
Requires Adobe Reader
6" Concrete Slab
Kinetics® KSCH Compact Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
2 Layers 5/8" Gypsum Board
59 47 C3-a
Requires Adobe Reader
6" Concrete Slab
Kinetics® KSCH Compact Ceiling Hanger
Rock Wool Batts
Cold Rolled Channel (CRC)
Drywall Furring Channel
2 Layers 5/8" Gypsum Board
72 51 C3-b
Requires Adobe Reader
Wood Flooring
4" Concrete Slab
Kinetics® LSM Isolator
2" Air Space, Vented
6" Structural Slab
  FIIC 72 D1-b
Requires Adobe Reader
Shredded Rubber Flooring
4" Concrete Slab
Kinetics® LSM Isolator
2" Air Space, Vented
6" Structural Slab
  FIIC 73 D1-c
Requires Adobe Reader
4" Reinforced Concrete Slab
Kinetics® FLM Isolator with Neoprene Pad
2" Air Space
6" Structural Slab
69 61 D2
Requires Adobe Reader
4" Reinforced Concrete Slab
Kinetics® FLM Isolator with Model KIP Pad
2" Air Space
6" Structural Slab
69 61 D3
Requires Adobe Reader
4" Reinforced Concrete Slab
Kinetics® FLM Isolator with Neoprene Pad
4" Air Space
6" Structural Slab
71 63 D4
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
5/8" Gypsum Board
57   E2-a
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
61   E2-b
Requires Adobe Reader
2 Layers of 5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
64   E2-c
Requires Adobe Reader
3 Layers of 5/8" Gypsum Board
2x6 Timber Framing
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
65   E2-d
Requires Adobe Reader
IsoMax Low Frequency Sound Transmission Loss (dB)
Kinetics Test Number Frequency (Hz)
31.5 40 50 63 80
E2-a 14 21 17 16 24
E2-b 16 22 20 23 30
E2-c 15 22 24 30 36
E2-d 14 24 32 39 38
Transmission Loss (TL) values were calculated at these additional test frequencies. Although the measurements were made in accordance with the procedures described in ASTM E90-99, they do not qualify as part of the standard. Since the results for these low frequencies are representative of the test environment only, they are unofficial and intended for research and development guidelines rather than for commercial purposes.
5/8" Gypsum Board
1-5/8" x 3-5/8" Steel Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
60   02153
Requires Adobe Reader
2 Layers of 5/8" Gypsum Board
1-5/8" x 3-5/8" Steel Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
63   02154
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
33   E1-a
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
Fiberglass Insulation
5/8" Gypsum Board
46   Wall
Retrofit
E1-b
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
52   Wall
Retrofit
E1-c
Requires Adobe Reader