Kinetics Noise Control
Home > Noise Control Building Materials > Soundmatt > STC/IIC Sound Test Data
KINETICS®

STC/IIC Sound Test Data | Soundmatt Noise Control Floor Underlayment

Description STC IIC Sections Test #
6" Concrete Slab 53 27 AT001049
Requires Adobe Reader
Wood Flooring
2 Layers 3/8" Plywood
5/16" KINETICS Soundmatt
1" Gypsum Concrete
5/8" Plywood
2x12 Joists
4" Mineral Fiber Batts
1/2" Resilient Channel
5/8" Fire-Rated Gypsum Board
58 54 AT001042
Requires Adobe Reader
Ceramic Tile
1/2" Wonderboard
5/16" KINETICS Soundmatt
with Roofing Felt Underlayment
5/8" Plywood
2x12 Joists
4" Mineral Fiber Batts
1/2" Resilient Channel
5/8" Fire-Rated Gypsum Board
63 54 AT001044
Requires Adobe Reader
Ceramic Tile
1/2" Wonderboard
5/16" KINETICS Soundmatt
6" Concrete Slab
60 53 AT001045
Requires Adobe Reader
Vinyl Floor Covering
1" Gypsum Concrete
3/4" Oriented Stand Board (OSB)
18" I-Joist
3" Mineral Fiber Batts
Resilient Channel
5/8" Gypsum Board
  FIIC 33
AT001046A
AT001046
Requires Adobe Reader
Vinyl Floor Covering
1" Gypsum Concrete
5/16" KINETICS Soundmatt
3/4" Oriented Stand Board (OSB)
18" I-Joist
3" Mineral Fiber Batts
Resilient Channel
5/8" Gypsum Board
  FIIC 51
AT001046B
AT001046
Requires Adobe Reader