Kinetics Noise Control - Vibration Isolation, Room Acoustics, Seismic Restraint Your source for Noise, Acoustic, Vibration and Seismic control systems, 1-877-457-2695
Home > Architectural Noise Separation > Sound Isolation Floor Systems > Model RIM > STC/IIC Sound Test Data
Sound Isolation Floor Systems

Kinetics™

Wood Floating Floors

Model RIM STC/IIC Sound Test Data

Description Acoustical Properties Sections Test #
STC IIC
1" Oak Hardwood Floor
3" Subfloor
  FIIC 15 A14-a
Requires Adobe Reader
3/4" Oak Hardwood Floor
3/4" Sleepers
1-1/2" Gypsum Concrete
2 Layers 1/2" Oriented Strand Board (OSB)
1" Kinetics® RIM L-1-16
1" Oak Hardwood Floor
3" Subfloor
FSTC 50 FIIC 45 A14-b
Requires Adobe Reader
3/8" Plywood
2 Layers 3/4" Plywood
2" Kinetics® RIM-I-2-16
6" Concrete Slab
66 63 A15-a
Requires Adobe Reader
3/8" Plywood
3/4" Plywood
2 Layers 5/8" Gypsum Board
3/4" Plywood
2" Kinetics® RIM-I-2-16
6" Concrete Slab
71 64 A15-b
Requires Adobe Reader