Kinetics Noise Control - Vibration Isolation, Room Acoustics, Seismic Restraint Your source for Noise, Acoustic, Vibration and Seismic control systems, 1-877-457-2695
Home > Architectural Noise Separation > Ceiling Isolation Systems/Wall Isolation Systems > Model IsoMax > STC/IIC Sound Test Data

Kinetics™

Resilient Sound Isolation Wall and Ceiling Clip

Model IsoMax STC/IIC Sound Test Data

Description STC IIC Sections Test #
6" Concrete Slab 53 27 B10
Requires Adobe Reader
3/8" Wood Floor
3/16" Kinetics® LP Soundmatt
6" Concrete Slab
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
2-1/2" Fiberglass Insulation compressed to 2"
5/8" Gypsum Board
61 58 B12
Requires Adobe Reader
6" Concrete Slab
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
2-1/2" Fiberglass Insulation compressed to 2"
5/8" Gypsum Board
66 44 C1
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
51 39 02146
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
54 57 02147
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
5/8" Gypsum Board
57   E2-a
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
61   E2-b
Requires Adobe Reader
2 Layers of 5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
64   E2-c
Requires Adobe Reader
3 Layers of 5/8" Gypsum Board
2x6 Timber Framing
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
65   E2-d
Requires Adobe Reader
IsoMax Low Frequency Sound Transmission Loss (dB)
Kinetics Test Number Frequency (Hz)
31.5 40 50 63 80
E2-a 14 21 17 16 24
E2-b 16 22 20 23 30
E2-c 15 22 24 30 36
E2-d 14 24 32 39 38
Transmission Loss (TL) values were calculated at these additional test frequencies. Although the measurements were made in accordance with the procedures described in ASTM E90-99, they do not qualify as part of the standard. Since the results for these low frequencies are representative of the test environment only, they are unofficial and intended for research and development guidelines rather than for commercial purposes.
5/8" Gypsum Board
1-5/8" x 3-5/8" Steel Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
60   02153
Requires Adobe Reader
2 Layers of 5/8" Gypsum Board
1-5/8" x 3-5/8" Steel Stud
Fiberglass Insulation
Kinetics® IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
63   02154
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
33   E1-a
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
Fiberglass Insulation
5/8" Gypsum Board
46   Wall
Retrofit
E1-b
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
Kinetics® IsoMax Clips
1-1/2" Drywall Furring Channel
Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
52   Wall
Retrofit
E1-c
Requires Adobe Reader