Kinetics Noise Control - Vibration Isolation, Room Acoustics, Seismic Restraint Your source for Noise, Acoustic, Vibration and Seismic control systems, 1-877-457-2695
Home > Architectural Noise Separation > Ceiling Isolation Systems > Model ICW > Sound Test Data
Ceiling Isolation Systems

Kinetics™

Wood-Frame Ceiling Hanger

Model ICW Sound Test Data

Description Acoustical Properties Sections Test #
STC IIC
3/8" Wood Floor
1-1/2" Concrete Slab
5/8" Plywood
2x10 Joists
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
51 40 C2-a
Requires Adobe Reader
3/8" Wood Floor
1-1/2" Concrete Slab
3/4" Plywood
2x10 Joists
Kinetics® ICW Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
76 62 C2-b
Requires Adobe Reader
Carpet
3/8" Carpet Pad
1-1/2" Concrete Slab
5/8" Plywood
2x10 Joists
Kinetics® ICW Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
73 89 C2-c
Requires Adobe Reader
3/8" Wood Floor
3/4" Plywood
2x10 Joists
Kinetics® ICW Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
59 52 C2-h
Requires Adobe Reader