Design No. L581

Floor/Ceiling Assembly using various structural wood and wood/steel members. See Item 6 in listing. Use two (2) layers gypsum board for superior sound control and 1-hour unrestrained assembly rating.

Design No. L521

Floor/Ceiling Assembly using parallel chord wood trusses. See Item 6C in listing. Use two (2) layers of gypsum board for superior sound control and 1-hour unrestrained assembly rating.

Design No. P522

Roof/Ceiling Assembly using either pitched or parallel chord wood trusses. See Item 6B in listing. Use two (2) layers gypsum board for superior sound control and 1-hour unrestrained assembly rating.